HOME marketing@nivelco.com + 36 -1 - 889-0100


 

 Offer – Print – More devices 
 NIVOCAP - CAPACITANCE LEVEL TRANSMITTER
C ? ? ? ? ? ?

 Type
C
 Version / Max. temperature
C
T Transmitter / 130 °C (266 °F)
B Transmitter with local LCD indicator / 130 °C (266 °F)
H Transmitter / 200 °C (392 °F)
P Transmitter with local LCD indicator / 200 °C (392 °F)
 Process connection size / Insulation
C
M ¾" BSP / Fully PFA insulated stainless steel
Z ¾" NPT / Fully PFA insulated stainless steel
R 1" BSP / Fully PFA insulated stainless steel
P 1" BSP / Partially PFA insulated stainless steel
A 1" NPT / Fully PFA insulated stainless steel
C 1" NPT / Partially PFA insulated stainless steel
S 1½ " BSP / Fully PFA insulated stainless steel
T 1½ " BSP / Partially PFA insulated stainless steel
B 1½ " NPT / Fully PFA insulated stainless steel
D 1½ " NPT / Partially PFA insulated stainless steel
 Housing
C
2 Aluminium (paint coated)
3 Plastic, PBT, glass fibre reinforced
4 * Stainless steel
 * Ex version under approval
 Probe length*
C
 Fully PFA insulated
0 2 0.2 m
n n 0.3 – 3 m; each started 100 mm
 Partially PFA insulated
0 2 0.2 m
n n 0.3 – 3 m; each started 100 mm
 nn = 03 – 30 : 0.3 – 3 m
* Contact NIVELCO USA for freight quote when quoting rigid probe length over 100 inches
 Output / Approval
C
2 4 – 20 mA
4 4 – 20 mA + HART®
6 4 – 20 mA / Ex ia G
8 4 – 20 mA+ HART® / Ex ia G

C ? ? ? ? ? ?
 Offer – Print – More devices 

 



CTR-200/300