HOME marketing@nivelco.com + 36 -1 - 889-0100


 

 Offer – Print – More devices 
 ECHOTREK - ULTRASONIC LEVEL TRANSMITTER
S ? ? 4 ? ? ?

 Type
S 4
6 1.15-33 ft (0.35-10 m; 60 kHz, Min. required flange size: DN80)
4 1.5-50 ft (0.45-15 m; 40 kHz, Min. required flange size: DN125)
2 2-82 ft (0.6-25 m; 20 kHz, Min. required flange size: DN150)
 Programmer and local indicator (SAP-200)
S 4
T Not included
B Included
 Housing / Transducer material
S 4
P Plastic, PBT, glass fibre reinforced / Polypropylene (PP)
V Plastic, PBT, glass fibre reinforced / PVDF
A Aluminium (paint coated) / Polypropylene (PP)
B Aluminium (paint coated) / PVDF
 Mounting
S 4
 DIN flanges: Polypropylene (PP), drilled like PN16
2 DN80 PN16
3 DN100 PN16
4 DN125 PN16
5 DN150 PN16
6 DN200 PN16
 FF ANSI flanges: Polypropylene (PP), drilled like 150 psi
A 3" FF 150 psi
B 4" FF 150 psi
C 5" FF 150 psi
D 6" FF 150 psi
E 8" FF 150 psi
 JIS flanges: Polypropylene (PP), drilled like 10K
G 80A (as per 10K)
H 100A (as per 10K)
P 125A (as per 10K)
R 150A (as per 10K)
S 200A (as per 10K)
 Mounting brackets
K 200 mm mounting bracket, paint coated steel
L 500 mm mounting bracket, paint coated steel
M 700 mm mounting bracket, paint coated steel
 Power supply / Output
S 4
1 85-255 V AC / 4-20 mA + DPDT
3 85-255 V AC / 4-20 mA + HART + DPDT
G 85-255 V AC / 4-20 mA + HART + DPDT + Data logging feature
K 85-255 V AC / 4-20 mA + DPDT + Data logging feature
2 24 V AC/DC / 4-20 mA + DPDT
4 24 V AC/DC / 4-20 mA + HART + DPDT
H 24 V AC/DC / 4-20 mA + HART + DPDT + Data logging feature
L 24 V AC/DC / 4-20 mA + DPDT + Data logging feature

S ? ? 4 ? ? ?
 Offer – Print – More devices 

 



ST_-46_






ST_-44_






ST_-44_