HOME marketing@nivelco.com + 36 -1 - 889-0100


 

 Offer – Print – More devices 
 MICROTREK - TDR LEVEL TRANSMITTER
H ? ? ? ? ? ?

 Type
H
 Version / Temperature
H
T Transmitter / Flange temperature max. 90 °C (194 °F)
H Transmitter / Flange temp. max. 200 °C (392 °F) (M type only up to 175°C [347°F])
B Transmitter with local LCD indicator / Flange temperature max. 90 °C (194 °F)
P Transmitter with local LCD indicator / Flange temp. max. 200 °C (392 °F) (M type only up to 175°C [347°F])
 Probe / Process connection
H
K Mono cable, Ø4 mm, 1.4401 / 1" BSP / max. 24 m
L Mono cable, Ø4 mm, 1.4401 / 1" NPT / max. 24 m
V Mono cable, Ø4 mm, 1.4401 / 1½ " BSP / max. 24 m
W Mono cable, Ø4 mm, 1.4401 / 1½ " NPT / max. 24 m
N Mono cable, Ø8 mm, 1.4401 / 1½ " BSP / max. 24 m
J Mono cable, Ø8 mm, 1.4401 / 1½ " NPT / max. 24 m
T Twin cable, 2x Ø4 mm, 1.4401 / 1½ " BSP / max. 24 m
U Twin cable, 2x Ø4 mm, 1.4401 / 1½ " NPT / max. 24 m
F * Mono cable, Ø4 mm, + FEP coated / 1" BSP / max. 24 m
G * Mono cable, Ø4 mm, + FEP coated / 1" NPT / max. 24 m
X * Mono cable, Ø4 mm, + FEP coated / TriClamp 1½ " / max. 24 m
Y * Mono cable, Ø4 mm, + FEP coated / Sanitary DN40 / max. 24 m
M Mono cable, Ø4 mm, + PFA/FEP fully coated / DN50, PN25, 1.4571 + PFA/FEP lining
 * Only the probe cable is coated, the probe weight is not
 Housing
H
4 Aluminium (paint coated)
5 Plastic, PBT, glass fibre reinforced (Ex version not available)
6 Stainless steel
 Probe length
H
n n 1.0 – 24.0 m (each 1 m), for mono cable, Ø4 mm, 1.4401
n n 1.0 – 24.0 m (each 1 m), for mono cable, Ø8 mm, 1.4401
n n 1.0 – 24.0 m (each 1 m), for twin cable, 1.4401
n n 1.0 – 24.0 m (each 1 m), for mono cable, Ø4 mm, 1.4401 + FEP
 nn = 01 – 24 : 1.0 – 24.0 m
 Output / Approval
H
4 4 – 20 mA + HART®
5 4 – 20 mA + HART® / Ex ta/tb D
6 4 – 20 mA + HART® / Ex ia D
8 4 – 20 mA + HART® / Ex ia G (in case of plastic coated probes only Ex ia IIB)

H ? ? ? ? ? ?
 Offer – Print – More devices 

 



H_K 400/500 + H_N-400/500






H_T-400/500 + H_F-400/500






H_X-400/500 + H_Y-400/500